ATAGO Digital Bench-top Refractometers are designed to be highly accurate and provide reliable measurements while facilitating a simple measurement method for the operator. When compared to analog and Abbe Refractometers, the large digital readout makes reading the measurement value faster and easier.

RX-α series

A Wide Selection to Meet
Every Measurement Need

RX-i series

The worlds highest standard of technology now
available with touch screen.

Automatic Digital Refractometer RX-5000i-Plus

The most accurate refractometer in the world is now even more stylish, smart, and functional.
Featuring intuitive touch screen technology, the new RX-i series makes navigation and selection a breeze.
The RX-5000i-Plus measures with the same accuracy level as the RX-5000α-Plus - 0.010% Brix and 0.00002 nD.
The RX-i series come with newly added functions, such as USB flash drive and self-diagnosis capability.
This product is warranted for a two (2) year limited warranty against manufacturers defects from the date of the original purchase. This warranty does not cover or apply to the touchscreen. The warranty period can be extended to three (3) years if the product is registered with ATAGO.


Enlargement
Quantity

>about the icons RS-232C Interface External temperature samples User scales can be inputted Measurement at a set temperature Calibration with water Digital display AC outlet (AC100 to 240V) Refractive index scale
Model RX-5000i-Plus Cat.No. 3275
Measurement Range Refractive index (nD) : 1.32422 to 1.58000
Brix : 0.000 to 100.000%
( 5 to 75°C ATC)
Minimum indication Refractive index (nD) : 0.00001
Brix : 0.005%
Temperature: 0.01°C
Measurement Accuracy Refractive index (nD) :
±0.00002
Brix : ±0.010%
Temperature control range 5.00 to 75.00°C
(No lower than 10C below the ambient temperature and no higher than 55C above the ambient temperature)
Repeatability Refractive index : ±0.00001 Brix : ±0.010% Power Supply AC100V to 240V, 50/60Hz
Mode 4 types Dimensions & weight 37×26×14cm, 6.6kg
(Main Unit only)
Power consumption 70VA
Output terminals • Printer (for ATAGO digital printers)
• Computer -USB
Warranty period 2 years (extended to 3 years if the product is registered)
Optional Digital Printer DP-63 : Cat.No.3118
Digital Printer DP-AD : Cat.No.3123
• Volatile sample adapter (metal) : RE-56167
• Volatile sample adapter (resin) : RE-56168
• Flow cell attachment : RE-56172
10% Sucrose (±0.01%) : RE-111001
20% Sucrose (±0.01%) : RE-112001
30% Sucrose (±0.01%) : RE-113001
40% Sucrose (±0.02%) : RE-114002
50% Sucrose (±0.02%) : RE-115002
* Calibration Certificate : Contact an ATAGO representative for details.
Parts Printer paper (regular) for DP-63 : RE-8412
Printer paper (long-term storage)for DP-63 : RE-8414
Printer paper for DP-AD : RE-89403
Ribbon cassette for DP-AD : RE-89402
• Fan Filter Replacement : RE-58001
Catalog Download
Go to the product search GO TOP

Automatic Digital Refractometer RX-5000i

The most accurate refractometer in the world is now even more stylish, smart, and functional.
Featuring intuitive touch screen technology, the new RX-i series makes navigation and selection a breeze.
The RX-5000i measures with the same accuracy level as the RX-5000α 0.03% Brix and 0.00004 nD.
The RX-i series come with newly added functions, such as USB flash drive and self-diagnosis capability.
This product is warranted for a two (2) year limited warranty against manufacturers defects from the date of the original purchase. This warranty does not cover or apply to the touchscreen. The warranty period can be extended to three (3) years if the product is registered with ATAGO.


Enlargement
Quantity

>about the icons RS-232C Interface External temperature samples User scales can be inputted Measurement at a set temperature Calibration with water Digital display AC outlet (AC100 to 240V) Refractive index scale
Model RX-5000i Cat.No. 3276
Measurement Range Refractive index (nD) : 1.32422 to 1.58000
Brix : 0.00 to 100.00%
( 5 to 75°C ATC)
Minimum indication Refractive index (nD) : 0.00001
Brix : 0.01%
Temperature: 0.01°C
Measurement Accuracy Refractive index (nD) :
±0.00004
Brix : ±0.03%
Temperature control range 5.00 to 75.00C
(No lower than 10C below the ambient temperature and no higher than 55C above the ambient temperature)
Repeatability Refractive index : ±0.00002
Brix : ±0.03%
Power Supply AC100V to 240V, 50/60Hz
Mode 4 types Dimensions & weight 37×26×14cm, 6.6kg
(Main Unit only)
Power consumption 70VA
Output terminals • Printer (for ATAGO digital printers)
• Computer -USB
Warranty period 2 years (extended to 3 years if the product is registered)
Optional Digital Printer DP-63 : Cat.No.3118
Digital Printer DP-AD : Cat.No.3123
• Volatile sample adapter (metal) : RE-56167
• Volatile sample adapter (resin) : RE-56168
• Flow cell attachment : RE-56172
10% Sucrose (±0.01%) : RE-111001
20% Sucrose (±0.01%) : RE-112001
30% Sucrose (±0.01%) : RE-113001
40% Sucrose (±0.02%) : RE-114002
50% Sucrose (±0.02%) : RE-115002
* Calibration Certificate : Contact an ATAGO representative for details.
Parts Printer paper (regular) for DP-63 : RE-8412
Printer paper (long-term storage)for DP-63 : RE-8414
Printer paper for DP-AD : RE-89403
Ribbon cassette for DP-AD : RE-89402
• Fan Filter Replacement : RE-58001
Catalog Download
Go to the product search GO TOP

Automatic Digital Refractometer RX-5000α-Plus

The NEW RX-5000α (alpha)-Plus features improved accuracy over the RX-5000α-Plus, with Brix ±0.010 and nD ±0.00002. The RX-5000α-Plus is an automatic digital refractometer which can set measurement temperature internally and has the following features for measuring the refractive index, Brix or concentration of various liquids accurately and speedily

• Since the RX-5000α-Plus has a thermo-module to control temperature, a constant temperature water bath is not necessary.
• The measurement starts automatically after the sample reaches your targeted temperature.
• The refractive index and Brix at your targeted temperature are speedily displayed.
• High Brix ± 0.01% and refractive index ± 0.00002 accuracy can be obtained.
• The RX-5000α-Plus displays the top-and-bottom-limit-bar for your set control range.
• If the measurement value differs from that of your Standard Liquid or the other refractometer, it can be adjusted in a certain range.
• 60 kinds of user scales can be input according to your sample.
• The RX-5000α-Plus is capable of calling up 30 latest measurements.
This product is warranted for a two (2) year limited warranty against manufacturers defects from the date of the original purchase. This warranty does not cover or apply to the prism. The warranty period can be extended to three (3) years if the product is registered with ATAGO.


Enlargement
Quantity

>about the icons RS-232C Interface External temperature samples User scales can be inputted Measurement at a set temperature Calibration with water Digital display AC outlet (AC100 to 240V) Refractive index scale
Model RX-5000α-Plus Cat.No. 3266
Measurement Range Refractive index (nD) : 1.32700 to 1.58000
Brix : 0.000 to 100.000%
( 5 to 60°C ATC)
Minimum indication Refractive index (nD) : 0.00001
Brix : 0.005%
Temperature: 0.01°C
Measurement Accuracy Refractive index (nD) :
±0.00002
Brix : ±0.010%
Measurement Temperature 5 to 60°C
Repeatability Refractive index : ±0.00001 Brix : ±0.010% Power Supply AC100V to 240V, 50/60Hz
Mode 3 types Dimensions & weight 37×26×14cm, 6.4kg
(Main Unit only)
Power consumption 65VA
Output terminals • Printer (for ATAGO digital printers)
• Computer - RS-232C
    Connection to a USB port requires a USB to RS-232 adapter (optional)
Warranty period 2 years (extended to 3 years if the product is registered)
Optional • Digital Printer DP-RX : Cat.No.3121
• Digital Printer DP-RD : Cat.No.3122
• Volatile sample adapter for RX-5000α : RE-56151
• Flow cell attachment for RX-5000α : RE-56156
10% Sucrose (±0.01%) : RE-111001
20% Sucrose (±0.01%) : RE-112001
30% Sucrose (±0.01%) : RE-113001
40% Sucrose (±0.02%) : RE-114002
50% Sucrose (±0.02%) : RE-115002
* Calibration Certificate : Contact an ATAGO representative for details.
Parts • Cover plate for RX-5000α : RE-6532
Printer paper (regular) for DP-62α, DP-RX : RE-8412
Printer paper (long-term storage)for DP-62α, DP-RX : RE-8414
Printer paper for DP-RD : RE-89403
Ribbon cassette for DP-RD : RE-89402
• Fan Filter Replacement : RE-58001
Catalog Download
Go to the product search GO TOP

Automatic Digital Refractometer RX-5000α

The RX-5000α ( alpha ) is an automatic digital refractometer which can set measurement temperature internally and has the following features for measuring the refractive index, Brix or concentration of various liquids accurately and speedily

• Since the RX-5000α ( alpha ) has a thermo-module to control temperature, a constant temperature water bath is not necessary.
• The measurement starts automatically after the sample reaches your targeted temperature.
• The refractive index and Brix at your targeted temperature are speedily displayed.
• High Brix ± 0.03% and refractive index ± 0.00004 accuracy can be obtained.
• The RX-5000α ( alpha ) displays the top-and-bottom-limit-bar for your set control range.
• If the measurement value differs from that of your Standard Liquid or the other refractometer, it can be adjusted in a certain range.
• 60 kinds of user scales can be input according to your sample.
• The RX-5000α ( alpha ) is capable of calling up 30 latest measurements.

*Special model of RX-5000α allows pre-programming of an additional scale (such as honey moisture, inverted sugar%, salt concentration or butyro) in addition to Refractive Index and Brix (%) at customer's request.
This product is warranted for a two (2) year limited warranty against manufacturers defects from the date of the original purchase. This warranty does not cover or apply to the prism. The warranty period can be extended to three (3) years if the product is registered with ATAGO.


Enlargement
Quantity

>about the icons RS-232C Interface External temperature samples User scales can be inputted Measurement at a set temperature Calibration with water Digital display AC outlet (AC100 to 240V) Refractive index scale
Model RX-5000α Cat.No. 3261
Measurement Range Refractive index (nD) : 1.32700 to 1.58000
Brix : 0.00 to 100.00%
( 5 to 60°C ATC)
Minimum indication Refractive index (nD) : 0.00001
Brix : 0.01%
Temperature: 0.01°C
Measurement Accuracy Refractive index (nD) : ±0.00004
Brix : ±0.03%
Measurement Temperature 5 to 60°C
Repeatability Refractive index : ±0.00002
Brix : ±0.01%
Power Supply AC100V to 240V, 50/60Hz
Mode 3 types Dimensions & weight 37×26×14cm, 6.4kg
(Main Unit only)
Power consumption 65VA
Output terminals • Printer (for ATAGO digital printers)
• Computer - RS-232C
    Connection to a USB port requires a USB to RS-232 adapter (optional)
Warranty period 2 years (extended to 3 years if the product is registered)
Optional • Digital Printer DP-RX : Cat.No.3121
• Digital Printer DP-RD : Cat.No.3122
• Digital printer DP-62α : Cat.No.3019
• Volatile sample adapter for RX-5000α : RE-56151
• Flow cell attachment for RX-5000α : RE-56156
10% Sucrose (±0.01%) : RE-111001
20% Sucrose (±0.01%) : RE-112001
30% Sucrose (±0.01%) : RE-113001
40% Sucrose (±0.02%) : RE-114002
50% Sucrose (±0.02%) : RE-115002
* Calibration Certificate : Contact an ATAGO representative for details.
Parts • Cover plate for RX-5000α : RE-6532
Printer paper (regular) for DP-62α, DP-RX : RE-8412
Printer paper (long-term storage)for DP-62α, DP-RX : RE-8414
Printer paper for DP-RD : RE-89403
Ribbon cassette for DP-RD : RE-89402
• Fan Filter Replacement : RE-58001
Catalog Download
Go to the product search GO TOP

Automatic Digital Refractometer RX-5000α-Bev

The NEW RX-5000α-Bev is a re-designed version of the conventional RX-5000α. A flat sample stage replaced the sample well to make it easier to wipe off the sample and to allow for a faster and easier clean up. The RX-5000α-Bev is ideal for measuring beverages and is equipped with all the standard features of the RX-5000α.
This product is warranted for a two (2) year limited warranty against manufacturers defects from the date of the original purchase. This warranty does not cover or apply to the prism. The warranty period can be extended to three (3) years if the product is registered with ATAGO.

Enlargement
Quantity

>about the icons RS-232C Interface External temperature samples User scales can be inputted Measurement at a set temperature Calibration with water Digital display AC outlet (AC100 to 240V) Refractive index scale
Model RX-5000α-Bev Cat.No. 3271
Measurement Range Refractive index (nD) : 1.32700 to 1.58000
Brix : 0.00 to 100.00%
( 5 to 60°C ATC)
Minimum indication Refractive index (nD) : 0.00001
Brix : 0.01%
Temperature: 0.01°C
Measurement Accuracy Refractive index (nD) : ±0.00004
Brix : ±0.03%
Measurement Temperature 5 to 60°C
Repeatability Refractive index : ±0.00002
Brix : ±0.01%
Power Supply AC100V to 240V, 50/60Hz
Mode 3 types Dimensions & weight 37×26×14cm, 6.4kg
(Main Unit only)
Power consumption 65VA
Output terminals • Printer (for ATAGO digital printers)
• Computer - RS-232C
    Connection to a USB port requires a USB to RS-232 adapter (optional)
Warranty period 2 years (extended to 3 years if the product is registered)
Optional • Digital printer DP-RX : Cat.No.3121
• Digital printer DP-RD : Cat.No.3122
10% Sucrose (±0.01%) : RE-111001
20% Sucrose (±0.01%) : RE-112001
30% Sucrose (±0.01%) : RE-113001
40% Sucrose (±0.02%) : RE-114002
50% Sucrose (±0.02%) : RE-115002
* Calibration Certificate : Contact an ATAGO representative for details.
Parts • Cover plate for RX-5000α-Bev : RE-65159
Printer paper (regular) for DP-RX : RE-8412
Printer paper (long-term storage) for DP-RX : RE-8414
Printer paper for DP-RD : RE-89403
Ribbon cassette for DP-RD : RE-89402
• Fan Filter Replacement : RE-58001
Catalog Download
Go to the product search GO TOP

Automatic Digital Refractometer RX-7000α

The RX-7000α ( alpha ) is an improved ( upgraded ) model for a measurement range of refractive index and measurement temperature of an RX-5000α ( alpha ). The thermo module for constant temperature is equipped.
It is best for measuring oils and fats of high melt point, higher refractive index perfumes, organic solvents, etc. The RX-7000α ( alpha ) has the manual calibration facility which compensate difference in standard liquids and measurement values by other refractometers.
This product is warranted for a two (2) year limited warranty against manufacturers defects from the date of the original purchase. This warranty does not cover or apply to the prism. The warranty period can be extended to three (3) years if the product is registered with ATAGO.


Enlargement
Quantity

>about the icons RS-232C Interface User scales can be inputted Measurement at a set temperature External temperature samples High temperature samples Calibration with water Digital display AC outlet (AC100 to 240V) Refractive index scale
Model RX-7000α Cat.No. 3262
Measurement Range Refractive index (nD)
1.3250 to 1.7000
Brix 0.00 to 100.0%
(ATC : 5 to 70°C)
Minimum Indication 0.0001or 0.00001
(by selection)
Brix 0.1% or 0.01%
(by selection)
Temperature: 0.01°C
Measurement Accuracy Refractive index (nD) ±0.0001
Brix ±0.1%
Measurement Temperature 5 to 70°C
Repeatability Refractive index : ±0.00005
Brix : ±0.02%
Power Supply AC100V to 240V, 50/60Hz
Mode 3 types Dimensions & weight 37×26×14cm, 6.9kg
(Main Unit only)
Power consumption 65VA
Output terminals • Printer (for ATAGO digital printers)
• Computer - RS-232C
    Connection to a USB port requires a USB to RS-232 adapter (optional)
Warranty period 2 years (extended to 3 years if the product is registered)
Optional • Digital Printer DP-RX : Cat.No.3121
• Digital Printer DP-RD : Cat.No.3122
• Digital Printer DP-62α : Cat.No.3019
• Volatile sample adapter for RX-7000α : RE-56152
• Flow cell attachment for RX-7000α : RE-56155
10% Sucrose (±0.01%) : RE-111001
20% Sucrose (±0.01%) : RE-112001
30% Sucrose (±0.01%) : RE-113001
40% Sucrose (±0.02%) : RE-114002
50% Sucrose (±0.02%) : RE-115002
* Calibration Certificate : Contact an ATAGO representative for details.
Parts • Cover plate for RX-7000α : RE-6532
Printer paper (regular) for DP-62α, DP-RX : RE-8412
Printer paper (long-term storage) for DP-62α, DP-RX : RE-8414
Printer paper for DP-RD : RE-89403
Ribbon cassette for DP-RD : RE-89402
• Fan Filter Replacement : RE-58001
Catalog Download
Go to the product search GO TOP

Automatic Digital Refractometer RX-9000α

The RX-9000α is a fully automatic digital refractometer with the highest level of accuracy of its kind.
Designed with a wide measurement range, measurement temperature range, and highest measurement accuracy, this instrument is suitable for multiple sample types ; such as measuring oils and fats with high melting points, aroma oils of high refractive index and organic solvents, meeting demands for high accuracy measurements.
The RX-9000α has a built-in Peltier thermo module for maintaining a constant sample temperature while taking measurements. Manual calibration is also possible to adjust to standard liquid values and to correct differences in measurement values between instruments.
This product is warranted for a two (2) year limited warranty against manufacturers defects from the date of the original purchase. This warranty does not cover or apply to the prism. The warranty period can be extended to three (3) years if the product is registered with ATAGO.

Enlargement
Quantity

>about the icons RS-232C Interface User scales can be inputted Measurement at a set temperature External temperature samples High temperature samples Calibration with water Digital display AC outlet (AC100 to 240V) Refractive index scale
Model RX-9000α Cat.No. 3263
Measurement Range Refractive index (nD) 1.32500 to 1.70000
Brix 0.00 to 100.00%
(ATC : 5 to 70°C)
Minimum Indication Refractive index (nD):0.00001 or 0.0001 (by selection)
Brix 0.01% or 0.1%
(by selection)
Temperature: 0.01°C
Measurement Accuracy Refractive index (nD) : ±0.00004
(nD 1.33299 to1.42009 at Measurement Temperature 10.00 to 30.00°C )
Refractive index (nD) : ±0.00010 (For ranges other than the above)
Brix±0.03% (Brix 0.00 to 50.00% at Measurement Temperature 10.00 to 30.00°C )
Brix±0.05% (Brix 50.01 to 95.00% at Measurement Temperature 10.00 to 30.00°C )
Brix±0.10% (For ranges other than the above, with Sucrose solution by MODE1)
Repeatability Refractive index (nD) : ±0.00002
(nD 1.33299 to1.42009 at Measurement Temperature 10.00 to 30.00°C )
Refractive index (nD) : ±0.00005 (For ranges other than the above)
Brix±0.01% (Brix 0.00 to 50.00% at Measurement Temperature 10.00 to 30.00°C )
Brix±0.02% (For ranges other than the above, with Sucrose solution by MODE1)
Measurement Temperature 5 to 70°C Power Supply AC100V to 240V, 50/60Hz
Mode 3 types Dimensions & weight 37×26×14cm, 6.9kg
(Main Unit only)
Power consumption 65VA
Output terminals • Printer (for ATAGO digital printers)
• Computer - RS-232C
    Connection to a USB port requires a USB to RS-232 adapter (optional)
Warranty period 2 years (extended to 3 years if the product is registered)
Optional • Digital Printer DP-RX : Cat.No.3121
• Digital Printer DP-RD : Cat.No.3122
• Volatile sample adapter for RX-9000α : RE-56152
• Flow cell attachment for RX-9000α : RE-56155
10% Sucrose (±0.01%) : RE-111001
20% Sucrose (±0.01%) : RE-112001
30% Sucrose (±0.01%) : RE-113001
40% Sucrose (±0.02%) : RE-114002
50% Sucrose (±0.02%) : RE-115002
* Calibration Certificate : Contact an ATAGO representative for details.
Parts • Cover plate for RX-9000α : RE-6532
Printer paper (regular) for DP-RX : RE-8412
Printer paper (long-term storage)for DP-RX: RE-8414
Printer paper for DP-RD : RE-89403
Ribbon cassette for DP-RD : RE-89402
• Fan Filter Replacement : RE-58001
Catalog Download
Go to the product search GO TOP

Automatic Digital Refractometer RX-007α (alpha)

The NEW RX-007α (alpha) is suitable for measuring water soluble samples with very low concentrations (5.000% or less) such as tea (green tea, black tea, oolong tea) and low sugar beverages at a very high accuracy of ±0.005%.
This product is warranted for a two (2) year limited warranty against manufacturers defects from the date of the original purchase. This warranty does not cover or apply to the prism. The warranty period can be extended to three (3) years if the product is registered with ATAGO.


Enlargement
Quantity

>about the icons RS-232C Interface External temperature samples User scales can be inputted Measurement at a set temperature Calibration with water Digital display AC outlet (AC100 to 240V) Refractive index scale
Model RX-007α Cat.No. 3921
Measurement Range Brix 0.000 to 5.000%
Refractive index (RI)
1.330150 to 1.341500
Minimum Indication Brix 0.001%
Refractive index (RI) 0.000001
Temperature 0.01°C
Measurement Accuracy Brix ±0.005%, Refractive index (RI) ±0.000010 (at 20°C)
(under specified ambient temperature and constant temperature)
Measurement Temperature 15.00 to 30.00°C Power Supply AC100V to 240V, 50/60Hz
Mode 2 types Dimensions & Weight 37×26×14cm, 6.9kg
(Main Unit only)
Power consumption 85VA
Output Terminals • Printer (for ATAGO digital printers)
• Computer - RS-232C
    Connection to a USB port requires a USB to RS-232 adapter (optional)
Warranty period 2 years (extended to 3 years if the product is registered)
Optional • Digital Printer DP-RX : Cat.No.3121
• Digital Printer DP-RD : Cat.No.3122
* Calibration Certificate : Contact an ATAGO representative for details.
Parts • Cover plate for RX-007α : RE-56157
Printer paper (regular) for DP-RX : RE-8412
Printer paper (long-term storage)for DP-RX: RE-8414
Printer paper for DP-RD : RE-89403
Ribbon cassette for DP-RD : RE-89402
• Fan Filter Replacement : RE-58001
Catalog Download
Go to the product search GO TOP

Digital Refractometer RX-5000

The RX-5000 combines nozzle for connect a water bath instead of built -in thermo module. The RX-5000 is equipped with all the standard features of the RX-a series.
This product is warranted for a two (2) year limited warranty against manufacturers defects from the date of the original purchase. This warranty does not cover or apply to the prism. The warranty period can be extended to three (3) years if the product is registered with ATAGO.


Enlargement
Quantity
>about the icons RS-232C Interface User scales can be inputted Measurement at a set temperature External temperature samples Calibration with water Digital display AC outlet (AC100 to 240V) Refractive index scale
Model RX-5000 Cat.No. 3281
Measurement Range Refractive index (nD) 1.32700 to 1.58000
Brix 0.00 to 100.00%
Minimum Indication Refractive index (nD) 0.00001%
Brix 0.01%
Measurement Accuracy Refractive index (nD) ±0.00004
Brix ±0.03%
Measurement Temperature 5 to 60°C
Repeatability Refractive index : ±0.00002
Brix : ±0.01%
Power Supply AC100 to 240V, 50/60Hz
Ambient Temperature 5 to 40°C Dimensions & weight 37×26×14cm, 6.4kg
(Main Unit only)
Power consumption 30VA
Output terminals • Printer output ( Digital printer DP-RX is available as an Optional. )
• Computer - RS-232C
    Connection to a USB port requires a USB to RS-232 adapter (optional)
Warranty period 2 years (extended to 3 years if the product is registered)
Optional • Digital printer DP-RX : Cat.No.3121
• Digital Printer DP-RD : Cat.No.3122
10% Sucrose (±0.01%) : RE-111001
20% Sucrose (±0.01%) : RE-112001
30% Sucrose (±0.01%) : RE-113001
40% Sucrose (±0.02%) : RE-114002
50% Sucrose (±0.02%) : RE-115002
* Calibration Certificate : Contact an ATAGO representative for details.
Parts • Cover plate for RX-5000 : RE-6532
• Tube band : RE-8507
Printer paper (regular) for DP-62α, DP-RX : RE-8412
Printer paper (long-term storage) for DP-62α, DP-RX : RE-8414
Printer paper for DP-RD : RE-89403
Ribbon cassette for DP-RD : RE-89402
Go to the product search GO TOP

Automatic Refractometer SMART-1

The Brix, inverted sugar or High Fructose Corn Syrup concentration can be measured in a range of 0.00 to 95.00% and with a high accuracy of ± 0.05% !
The SMART-1 has Automatic Temperature Compensation function.
• Brix
• Inverted sugar concentration
• HFCS-55 ( High Fructose Corn Syrup )
• HFCS-42 ( High Fructose Corn Syrup )
This product is warranted for a two (2) year limited warranty against manufacturers defects from the date of the original purchase. This warranty does not cover or apply to the prism. The warranty period can be extended to three (3) years if the product is registered with ATAGO.


Enlargement
Quantity
>about the icons RS-232C Interface External temperature samples Calibration with water Digital display AC outlet (AC100 to 240V)
Model SMART-1 Cat.No. 3150
Measurement Range [1] Brix : 0.00 to 95.00 % ( ATC* )
[2] Inverted sugar concentration : 0.00 to 95.00 % ( ATC* )
[3] HFCS-55 ( High Fructose Corn Syrup ) : 0.00 to 95.00 % ( ATC* )
[4] HFCS-42 ( High Fructose Corn Syrup ) : 0.00 to 95.00 % ( ATC*)
*Automatic Temperature Compensation
Minimum Indication [1] Brix : 0.01 %
[2] Inverted sugar concentration : 0.01 %
[3] HFCS-55 ( High Fructose Corn Syrup ) : 0.01 %
[4] HFCS-42 ( High Fructose Corn Syrup ) : 0.01 %
Measurement Accuracy [1] Brix : ± 0.05 % ( on measurement of sucrose )
[2] Inverted sugar concentration : ± 0.05%
[3] HFCS-55 ( High Fructose Corn Syrup ) : ± 0.05 %
[4] HFCS-42 ( High Fructose Corn Syrup ) : ± 0.05 %
Repeatability [1] Brix : 0.01 %
[2] Inverted sugar concentration : 0.01 %
[3] HFCS-55 ( High Fructose Corn Syrup ) : 0.01 %
[4] HFCS-42 ( High Fructose Corn Syrup ) : 0.01 %
Measurement Temperature 5 to 40°C Power Supply AC100V to 240V, 50/60Hz
Power consumption 15VA
Dimensions & Weight 12×27×9cm, 2.0kg
(Main Unit only)
International Protection Class
IP64 ( Excluding AC adapter )
Dust-tight and Protected against splashing water.
Computer
Communication
Communication system :
RS-232C
Output Terminals (1) Digital Printer DP-22(A) (Optional) is used.
(2) Communication system: RS-232C
Warranty period 2 years (extended to 3 years if the product is registered)
Optional Digital Printer DP-22(A) Cat.No.3124
• RS-232C cable For Personal Computer : RE-45302
10% Sucrose Solution (±0.03%) : RE-110010
20% Sucrose Solution (±0.03%) : RE-110020
30% Sucrose Solution (±0.03%) : RE-110030
40% Sucrose Solution (±0.04%) : RE-110040
50% Sucrose Solution (±0.05%) : RE-110050
60% Sucrose Solution (±0.05%) : RE-110060
* Calibration Certificate : Contact an ATAGO representative for details.
Parts Printer paper (regular) for DP-22 : RE-8413
Printer paper (long-term storage)for DP-22 : RE-8415
Catalog Download
Go to the product search GO TOP

Digital Printer DP-22(A)

The DP-22(A) is a printer for Automatic Refractometer SMART-1(Serial No.092901~). It automatically prints out the number of samples, measurement results, and measured temperature whenever the refractometer completes measurement.


Enlargement
Quantity
Model DP-22(A) Cat.No. 3124
Printing method Thermal dot printing Power Supply From AC adapter ( Input voltage : AC100 to 240V )
Power Consumption 26VA Dimensions & Weight 14×10×4cm, 390g
(Main Unit only)
Optional * Calibration Certificate : Contact an ATAGO representative for details.
Parts Printer paper (regular) for DP-22 : RE-8413
Printer paper (long-term storage) for DP-22 : RE-8415
Go to the product search GO TOP

Digital Printer DP-22

The DP-22 is a printer for Automatic Refractometer SMART-1(Serial No.~092830). It automatically prints out the number of samples, measurement results, and measured temperature whenever the refractometer completes measurement.


Enlargement
Quantity
Model DP-22 Cat.No. 3013
Printing method Thermal dot printing Power Supply DC9V from the refractometer
Power Consumption 26VA Dimensions & Weight 14×10×4cm, 390g
(Main Unit only)
Optional * Calibration Certificate : Contact an ATAGO representative for details.
Parts Printer paper (regular) for DP-22 : RE-8413
Printer paper (long-term storage) for DP-22 : RE-8415
Go to the product search GO TOP

Digital Printer DP-62

The DP-62 is a printer for Digital Refractometer RX-5000. It automatically prints out the number of samples, measurement value for refractive index (nD or nDt), Brix (%), concentration (%) (one of user scales), and measurement temperature whenever the refractometer completes measurement.


Enlargement
Quantity
Model DP-62 Cat.No. 3018
Printing method Thermal dot printing Power Supply DC8.5V from the refractometer
Power consumption 13VA Dimensions & weight 17×16×7cm, 580g
(Main Unit only)
Optional * Calibration Certificate : Contact an ATAGO representative for details.
Parts Printer paper (regular) for DP-62 : RE-8412
Printer paper (long-term storage) for DP-62 : RE-8414
Go to the product search GO TOP

Digital Printer DP-62α

The DP-62α (alpha) is a printer for Automatic Digital Refractometer RX-5000α (alpha), RX-7000α (alpha). It automatically prints out the number of samples, measurement value for refractive index (nD or nDt), Brix (%), concentration (%) (one of user scales), and measurement temperature whenever the refractometer completes measurement.


Enlargement
Quantity
Model DP-62α Cat.No. 3019
Printing method Thermal dot printing Power Supply DC8.5V from the refractometer
Power consumption 13VA Dimensions & weight 17×16×7cm, 580g
(Main Unit only)
Optional * Calibration Certificate : Contact an ATAGO representative for details.
Parts Printer paper (regular) for DP-62α : RE-8412
Printer paper (long-term storage)for DP-62α : RE-8414
Go to the product search GO TOP

Digital Printer DP-RX

The DP-RX is suitable for RX-5000α having serial No. 052601 onwards and RX-7000α having serial No. 051301 onwards. It automatically prints out the number of samples, measurement value for refractive index (nD or nDt), Brix (%), concentration (%) (one of user scales), and measurement temperature whenever the refractometer completes measurement.


Enlargement
Quantity
Model DP-RX Cat.No. 3121
Printing method Thermal dot printing Power Supply From AC adapter ( Input voltage:AC100 to 240V )
Power consumption 13VA Dimensions & weight 17×16×7cm, 580g
(Main Unit only)
Optional * Calibration Certificate : Contact an ATAGO representative for details.
Parts Printer paper (regular) for DP-RX : RE-8412
Printer paper (long-term storage)for DP-RX: RE-8414
.iOYfy[fW,,,, GO TOP

Digital printer DP-RD

The DP-RD is a printer for Digital Refractometer RX-α series. It automatically prints out the number of samples, measurement value for refractive index (nD or nDt), Brix (%), concentration (%) (one of user scales), and measurement temperature whenever the refractometer completes measurement. The DP-RD uses regular rolled plain paper (not thermal).


Enlargement
Quantity
Model DP-RD Cat.No. 3122
Printing method Impact dot printing Power Supply From AC adapter ( Input voltage:AC100 to 240V )
Power consumption 7VA Dimensions & weight 11×18×9cm, 470g
(Main Uint only)
Optional * Calibration Certificate : Contact an ATAGO representative for details.
Parts Printer paper for DP-RD : RE-89403
Ribbon cassette for DP-RD : RE-89402
.iOYfy[fW,,,, GO TOP